WEBVTT

00:00:09.680 --> 00:00:13.896
Hello, good morning, everyone,
and thank you for being able to join us

00:00:13.896 --> 00:00:15.440
and taking the time today.

00:00:15.880 --> 00:00:17.920
We're really excited to have everyone
here.

00:00:17.920 --> 00:00:21.584
This is a really,
really unique event for us at AIP

00:00:21.584 --> 00:00:22.360
Publishing.

00:00:22.360 --> 00:00:29.680
You're joining during the first inaugural,
the first inaugural Bioscience webinar.

00:00:29.720 --> 00:00:34.513
And so we are really fortunate to hear
lightning style presentations from 4

00:00:34.513 --> 00:00:39.621
distinguished researchers working on the
cutting edge delivery of drug delivery,

00:00:39.621 --> 00:00:41.640
safety and and testing research.

00:00:42.080 --> 00:00:47.188
So today you have the fortune to hear
from Seth Sarkaya presenting on behalf of

00:00:47.188 --> 00:00:51.850
Doctor Horatio Dante Espinoza from
Northwestern University in the United

00:00:51.850 --> 00:00:53.000
States of America.

00:00:53.440 --> 00:00:58.000
You have Doctor Minjun's son from John
Zuckerberg Biohub in Chicago.

00:00:58.480 --> 00:01:03.267
You'll hear from Doctor Marco Rasponi
from the Polytechnical de Milano in Italy,

00:01:03.267 --> 00:01:06.400
and Doctor Ash Argawal from the
University of Miami.

00:01:07.000 --> 00:01:08.360
So we are very excited.

00:01:08.560 --> 00:01:09.640
Thank you for joining us.

00:01:09.640 --> 00:01:13.162
Whether it's morning,
evening or afternoon from you all across

00:01:13.162 --> 00:01:15.120
the world, this is a true pleasure.

00:01:16.040 --> 00:01:20.236
Today's conversation is going to be
moderated by Doctor ITAO of Nanjing

00:01:20.236 --> 00:01:23.092
University,
and he's also the editor in chief of

00:01:23.092 --> 00:01:24.200
Biophysics Reviews.

00:01:24.960 --> 00:01:27.280
Also on the call is Justin Cooper White.

00:01:27.280 --> 00:01:30.000
He's the editor in chief of APL
Bioengineering.

00:01:30.280 --> 00:01:33.531
And Leslie Yao,
he's the editor in chief of Bio

00:01:33.531 --> 00:01:34.480
Microfluidics.

00:01:35.360 --> 00:01:39.879
These three journals are the cornerstone
of AIP Publishing's bio portfolio,

00:01:39.879 --> 00:01:44.696
and it really is a rare treat for us to
be together and celebrate this excellent

00:01:44.696 --> 00:01:46.480
research across the portfolio.

00:01:47.280 --> 00:01:52.131
So now I'll turn it over to each of the
EI CS to introduce themselves and give

00:01:52.131 --> 00:01:57.350
you a little brief update on the journals,
their scopes and the visions that they've

00:01:57.350 --> 00:02:02.140
really created in the hopes that they
have in servicing you as researchers in

00:02:02.140 --> 00:02:03.000
the community.

00:02:03.480 --> 00:02:05.920
So first, I'd like our moderator, Dr.

00:02:05.920 --> 00:02:08.680
E Tao to share a few words about himself.

00:02:11.720 --> 00:02:12.720
Good morning everyone.

00:02:12.720 --> 00:02:17.520
I'm E Tao from Nanjing University and the
editor in chief of Biophysical Reviews.

00:02:17.880 --> 00:02:22.200
It's my great pleasure to be the
moderator of this webinar.

00:02:22.320 --> 00:02:27.533
And as we can see from the name of the
journal, Biophysical Review,

00:02:27.533 --> 00:02:33.513
it publish high quality cutting edge
reviews in the broad field of biophysics

00:02:33.513 --> 00:02:38.880
and not only review papers,
we also publish original research papers.

00:02:39.280 --> 00:02:47.040
And we just checked the recent general
impact factor is 4.5.

00:02:47.440 --> 00:02:54.148
So I think it's a good review journal and
I look forward to the submissions and

00:02:54.148 --> 00:02:58.760
we're looking forward to the discussions
this morning.

00:02:59.640 --> 00:03:00.000
Thank you.

00:03:02.680 --> 00:03:06.009
Thank you,
E very good hands with E as our moderator

00:03:06.009 --> 00:03:09.590
and as he said,
biophysics reviews and excellent journal

00:03:09.590 --> 00:03:12.920
publishing reviews,
research across the Biosciences.

00:03:13.440 --> 00:03:17.960
Next we have Doctor Justin Cooper White
of APL Bioengineering.

00:03:17.960 --> 00:03:21.243
Justin,
if you would like to say a few words,

00:03:21.243 --> 00:03:21.600
Sure.

00:03:21.600 --> 00:03:22.680
Thanks, Austin.

00:03:23.440 --> 00:03:24.160
Good morning.

00:03:24.160 --> 00:03:27.840
Good evening everyone joining in from
Australia.

00:03:27.840 --> 00:03:31.200
It's 11:00 PM over here,
so fairly night night for us.

00:03:32.240 --> 00:03:35.277
Leslie,
similarly late APL bioengineering has

00:03:35.277 --> 00:03:37.720
been going for a number of years now.

00:03:37.720 --> 00:03:43.378
We launched in 2017 and we we focus on
publishing papers, review articles,

00:03:43.378 --> 00:03:48.658
perspectives at the intersection of
biology, physics and engineering,

00:03:48.658 --> 00:03:53.411
and really looking at high impact
manuscripts that advance our

00:03:53.411 --> 00:03:58.240
understanding of physics and engineering
of biological systems.

00:03:58.520 --> 00:04:02.500
We cover a whole range of topical
coverage areas that you might expect by

00:04:02.500 --> 00:04:06.642
fabrication and by printing biomedical
materials, engineered living systems,

00:04:06.642 --> 00:04:09.440
cell and tissue engineering,
regenerative medicine,

00:04:09.440 --> 00:04:12.936
molecular cell and tissue,
bio mechanics and systems biology and

00:04:12.936 --> 00:04:14.120
computational biology.

00:04:14.400 --> 00:04:18.663
And it's certainly launched into the
space of AI and M machine learning in

00:04:18.663 --> 00:04:19.800
each of those areas.

00:04:20.200 --> 00:04:24.476
And we look forward to seeing your papers
whenever you'd like to submit them to APL

00:04:24.476 --> 00:04:25.240
Bioengineering.

00:04:25.240 --> 00:04:27.560
And thanks so much for attending the
webinar today.

00:04:29.200 --> 00:04:30.160
Thank you, Justin.

00:04:30.720 --> 00:04:35.048
APL Bioengineering has been one of our
newer APLX journals, you know,

00:04:35.048 --> 00:04:39.810
started and it's reached its decade of
publications and it's really been the

00:04:39.810 --> 00:04:44.881
landing point for the journal and for the
portfolio to touch researchers and help

00:04:44.881 --> 00:04:49.520
you expand the breadth and awareness you
have in the bioengineering space.

00:04:49.520 --> 00:04:51.600
So kudos to Justin.

00:04:52.160 --> 00:04:57.891
And now I would like to let Doctor Leslie
Yao bio microfluidics say a few words and

00:04:57.891 --> 00:04:59.120
introduce history.

00:05:00.800 --> 00:05:01.640
Thanks, Austin.

00:05:02.120 --> 00:05:06.080
So Leslio calling in from Melbourne,
Australia.

00:05:07.360 --> 00:05:10.320
I'm the end of the in chief of bio
microfluidics.

00:05:11.160 --> 00:05:19.132
So BMF exists to, you know,
publish the fundamental and applied

00:05:19.132 --> 00:05:28.474
research in all all scope across bio,
micro and nano fluidic and transport

00:05:28.474 --> 00:05:29.720
phenomena.

00:05:30.320 --> 00:05:38.417
Now the contrary to common perception
that it has to be bio micro and fluidics,

00:05:38.417 --> 00:05:40.240
it's actually ore.

00:05:40.720 --> 00:05:47.480
So we publish across all that all,
all throughout the the the ranges.

00:05:47.480 --> 00:05:52.230
So, you know,
whether it's biofluidics or microfluidics

00:05:52.230 --> 00:05:57.320
or nanofluidics, nano transport,
we accept all that papers.

00:05:58.480 --> 00:06:03.571
And what we like to do is to being a
society based journal,

00:06:03.571 --> 00:06:09.850
we like to partner with, you know,
the community to publish strong papers

00:06:09.850 --> 00:06:15.450
that are not just show and tell, you know,
in, you know, devices,

00:06:15.450 --> 00:06:18.760
but also strong in fundamental science.

00:06:19.080 --> 00:06:23.960
And that's what we've been strong and
known for.

00:06:24.320 --> 00:06:25.920
So thank you for joining us.

00:06:26.400 --> 00:06:32.520
We really appreciate it and really
excited about this first webinar.

00:06:33.160 --> 00:06:33.920
Thanks, everyone.

00:06:35.480 --> 00:06:36.600
Thank you so much, Leslie.

00:06:36.640 --> 00:06:40.065
And as you see,
we have the opportunity to pull just

00:06:40.065 --> 00:06:45.430
popped up on your page for most of you as
participants and we just wanted to get a

00:06:45.430 --> 00:06:48.080
sense of what brought you to the webinar.

00:06:48.280 --> 00:06:52.698
We're excited to have you here no matter
what time zone you're joining from and

00:06:52.698 --> 00:06:57.116
would love to know which of the journals
you're most familiar with or if you're

00:06:57.116 --> 00:06:59.160
not familiar with any of them at all.

00:06:59.560 --> 00:07:02.756
It's really appreciate your time and
we'll want to do everything we can to

00:07:02.756 --> 00:07:06.080
make sure you get the information about
the journals that matter most to you.

00:07:08.160 --> 00:07:10.946
So with that,
as you populate those answers,

00:07:10.946 --> 00:07:12.680
feel free to take your time.

00:07:12.720 --> 00:07:17.207
They'll they'll be live and updated
during the course of this webinar,

00:07:17.207 --> 00:07:19.040
so I won't delay any further.

00:07:19.320 --> 00:07:21.760
I know you're all very eager to hear from
our speakers.

00:07:22.080 --> 00:07:25.974
So with that said,
I will allow you to introduce our first

00:07:25.974 --> 00:07:27.360
speakers for the day.

00:07:27.360 --> 00:07:33.680
The first speaker will be Doctor Song.

00:07:33.720 --> 00:07:49.666
Sorry would be 2nd so I need to the The
first talk will start from Doctor Minji

00:07:49.666 --> 00:07:57.640
Song from Chan Zuckberg by harp Chicago.

00:07:58.360 --> 00:08:04.160
He has leads the micro tissue signal
dynamics group.

00:08:04.240 --> 00:08:10.244
His research integrates micropholitics,
single cell analysis and the systems

00:08:10.244 --> 00:08:16.560
biology to understand how immune cells
process dynamic signal in space and time.

00:08:17.280 --> 00:08:22.514
Today he will discuss advanced
microfluidic technology for precise

00:08:22.514 --> 00:08:27.670
intracellular delivery,
genome editing and the real time analysis

00:08:27.670 --> 00:08:28.920
of living cells.

00:08:32.440 --> 00:08:34.320
The the slide is yours please.

00:08:35.360 --> 00:08:35.480
OK.

00:08:36.320 --> 00:08:38.120
Can you see my screen?

00:08:38.600 --> 00:08:39.520
Yes, we can.

00:08:39.520 --> 00:08:40.520
All right, cool.

00:08:40.960 --> 00:08:41.920
Yeah, Yeah.

00:08:41.920 --> 00:08:44.840
Thank you for the introductions and thank
you for this opportunity.

00:08:45.880 --> 00:08:52.027
So my lab is in Bio Chicago and my labs
specialize in especially specialize in

00:08:52.027 --> 00:08:58.019
developing the micro fluid devices for
the tissues and controls very tightly

00:08:58.019 --> 00:09:00.120
controls the fluids inside.

00:09:00.120 --> 00:09:04.553
And on the other hand,
Doctor Espinosa from Northwestern,

00:09:04.553 --> 00:09:09.904
he's labs specialize in plus of the
cytokine measurements through the

00:09:09.904 --> 00:09:11.280
plasmonic sensing.

00:09:11.280 --> 00:09:17.906
So we are collaborating this I mean
together to unable something very core

00:09:17.906 --> 00:09:19.320
that is to yeah.

00:09:19.320 --> 00:09:20.360
So I want to make core.

00:09:20.360 --> 00:09:25.688
I mean by combining our technologies,
we are trying to build a integrated

00:09:25.688 --> 00:09:27.560
platform where I can live.

00:09:27.720 --> 00:09:33.926
I mean from my lab I can leverage the
hydro microfluidics and to have like skin

00:09:33.926 --> 00:09:40.054
tissues or organoids are growing in many
tiny chambers and then to control the

00:09:40.054 --> 00:09:46.027
fluid and extract a little bit of each
fluid from each samples and then send

00:09:46.027 --> 00:09:49.751
them,
send them to the other chip where the the

00:09:49.751 --> 00:09:55.492
tools or the devices from the doctor
Espinosa can use a plasmodic sensing

00:09:55.492 --> 00:09:58.440
technologies to measure the cytokines.

00:09:58.920 --> 00:10:02.760
So through the micro fluid chips,
I can control the inputs.

00:10:02.760 --> 00:10:06.907
I can apply many like a TNFR file or LP's
want any combinatory,

00:10:06.907 --> 00:10:09.240
how many combinatories of the drugs.

00:10:09.680 --> 00:10:13.664
So these are the inputs and then these
can come in in different combinations or

00:10:13.664 --> 00:10:17.600
different dynamics and I can address each
chamber with these different inputs.

00:10:18.080 --> 00:10:21.612
And then the outputs,
I can do the like weird time 3D imaging

00:10:21.612 --> 00:10:25.942
at the same time send a little bit of
fluid from each sample to the another

00:10:25.942 --> 00:10:27.880
chip that has a plasmodic sensing.

00:10:28.160 --> 00:10:32.583
So if this is possible,
we can monitor like hundreds of tissues

00:10:32.583 --> 00:10:37.697
and we can monitor how they response to
the this stimulus dynamics or the

00:10:37.697 --> 00:10:39.840
combinatories stimulus stimuli.

00:10:39.840 --> 00:10:45.060
And we can measure like the forces
changes or say migration helping the

00:10:45.060 --> 00:10:45.640
tissues.

00:10:46.000 --> 00:10:49.654
At the same time we can measure the
cytokine secretion dynamics in the real

00:10:49.654 --> 00:10:50.280
time as well.

00:10:50.600 --> 00:10:52.400
So, yeah, this is our dream.

00:10:52.880 --> 00:10:55.320
And so this is divided into two phases.

00:10:55.400 --> 00:10:57.800
The first phase is a high throughput
microfluidics.

00:10:58.320 --> 00:11:02.967
And because it's a high throughput and
then there are many like automations

00:11:02.967 --> 00:11:05.720
necessary to run these experiments
actually.

00:11:06.040 --> 00:11:12.472
So my lab has developed this microfluidic
platform where it has a lot of arrays of

00:11:12.472 --> 00:11:18.440
chambers and then and also a lot of
controls to like a mixed input media and

00:11:18.440 --> 00:11:24.485
then send them to specific chambers or,
or to change the the medium condition

00:11:24.485 --> 00:11:29.600
where the cytokine conditions in each
chambers like continuously.

00:11:29.880 --> 00:11:34.600
So this the left picture shows the the
hydro platform that enables this.

00:11:35.080 --> 00:11:40.973
And on top of that,
because we also want to get more data

00:11:40.973 --> 00:11:43.920
through like a little bit of.

00:11:45.600 --> 00:11:48.640
So we want to print the tissues in a way
that we want.

00:11:48.640 --> 00:11:52.223
So if we just see the cells,
the amount of cells,

00:11:52.223 --> 00:11:55.520
cells city in each chamber will be
different.

00:11:55.520 --> 00:11:58.320
The how they form the organoid,
what the shape can be different.

00:11:58.840 --> 00:12:01.356
So,
but to make but that data would be

00:12:01.356 --> 00:12:02.840
difficult to interpret.

00:12:03.080 --> 00:12:05.703
So we built,
we have our own custom like robotic

00:12:05.703 --> 00:12:06.560
pipeline system.

00:12:06.760 --> 00:12:11.403
So we can actually print or see the
organoid in a specific uniform shape that

00:12:11.403 --> 00:12:11.880
we want.

00:12:12.640 --> 00:12:16.725
And also, I mean,
the last piece that's necessary is the

00:12:16.725 --> 00:12:17.800
the 3D imaging.

00:12:17.800 --> 00:12:22.280
So we have a kind of custom Kung Fu car.

00:12:23.720 --> 00:12:27.615
So I'm about to purchase a spinning this
Kung Fu car to facilitate the high

00:12:27.615 --> 00:12:29.000
throughput imaging as well.

00:12:29.200 --> 00:12:32.538
But for now,
we have a like AI mean we have a Kung Fu

00:12:32.538 --> 00:12:35.320
car system that we are unable to 3D
imaging.

00:12:35.320 --> 00:12:38.720
So from each samples in each chamber,
the chip.

00:12:39.520 --> 00:12:44.427
And just to briefly show you how, yeah,
how the system works,

00:12:44.427 --> 00:12:50.760
the left side shows the so these are all
these blue leader part is like a small

00:12:50.760 --> 00:12:54.560
chamber that we have organoid or tissues
in it.

00:12:54.920 --> 00:12:58.348
And all these left,
the holes on the left side is where the

00:12:58.348 --> 00:13:00.120
input media will be plugged in.

00:13:00.120 --> 00:13:04.334
It can be TNF, it can be LP's,
it can be IR 12 or some drugs that you

00:13:04.334 --> 00:13:05.840
can you can just imagine.

00:13:06.200 --> 00:13:11.352
And there are this many fine red lines
which has a variables to control which of

00:13:11.352 --> 00:13:15.360
these inputs will be mixed and then send
it to which chambers.

00:13:15.640 --> 00:13:17.560
So these are all controlled by the
computers.

00:13:17.600 --> 00:13:19.200
And then these all can be automated.

00:13:19.560 --> 00:13:22.640
And then the one in the middle shows the
how the tissue printing works.

00:13:23.120 --> 00:13:26.666
And then the image on the right side
shows that how it looks like when it's

00:13:26.666 --> 00:13:27.040
printed.

00:13:27.240 --> 00:13:33.122
So on the top you see that there's a
chamber filled with a so this black part

00:13:33.122 --> 00:13:34.480
is a deep chamber.

00:13:34.480 --> 00:13:38.400
It has a thickness about over about 500
micrometer or so.

00:13:38.840 --> 00:13:43.216
And then the the pictures on the bottom,
images on the bottom shows that how it

00:13:43.216 --> 00:13:45.240
looks like when the organ was saving.

00:13:47.680 --> 00:13:50.800
And this said we're take on.

00:13:50.800 --> 00:13:51.800
Yeah, yeah.

00:13:51.800 --> 00:13:52.680
Takes me in June.

00:13:53.880 --> 00:13:57.280
So yeah, here I'm,
my name is Serkit Sarika.

00:13:57.280 --> 00:13:59.520
I'm a post doc in Professor Espinoza.

00:13:59.560 --> 00:14:03.560
Unfortunately, he had a time conflict,
so he's not able to join.

00:14:04.680 --> 00:14:10.032
So this is a collaborative project with
Ming Jung's group and our group at

00:14:10.032 --> 00:14:10.960
Northwestern.

00:14:11.160 --> 00:14:15.880
So here we have a microfluidic device
with gold plasmonic sensor.

00:14:16.320 --> 00:14:21.905
So we functionalize the sensor for like
proteins of interest and then there's a

00:14:21.905 --> 00:14:24.000
binding to the sensor surface.

00:14:24.080 --> 00:14:26.040
The sensor reacts it optically.

00:14:26.040 --> 00:14:31.720
So we track the optical reaction in situ
with with microscopy and camera.

00:14:32.280 --> 00:14:37.785
So this microfluidic device allows the
sounds to stay alive for days while we do

00:14:37.785 --> 00:14:40.640
like continuously read the sensor outputs.

00:14:41.160 --> 00:14:47.012
So we can track like individual
inflammatory responses with high spatial

00:14:47.012 --> 00:14:53.186
and temporal resolution at the same time
like we can track the morphological

00:14:53.186 --> 00:14:59.440
changes and we can correlate these
morphological changes with the secretions.

00:15:00.360 --> 00:15:06.918
You can go to next slides yeah so before
any you know cell live cell work so we

00:15:06.918 --> 00:15:12.820
calibrated the sensor against like no
concentration of recombinant like

00:15:12.820 --> 00:15:13.640
cytokines.

00:15:13.640 --> 00:15:20.855
So these plots show the real time like
binding responses for TNF alpha and IR 6

00:15:20.855 --> 00:15:23.200
from 100 to 500 gig molar.

00:15:24.400 --> 00:15:29.800
The signal is like rises in in a clean
and concentration dependent way.

00:15:30.200 --> 00:15:35.646
So when the this let me plug response
against like concentration,

00:15:35.646 --> 00:15:40.680
both cytokines like you get linear fit to
the high R square.

00:15:42.080 --> 00:15:47.529
So that means like we can convert this
optical signal directly into absolute

00:15:47.529 --> 00:15:49.440
like protein concentration.

00:15:49.440 --> 00:15:55.569
It's an important to back calculate the
cell responses into the amount of

00:15:55.569 --> 00:15:57.640
secretion they have next.

00:15:58.280 --> 00:16:03.297
Yeah so with that calibration we moved to,
you know,

00:16:03.297 --> 00:16:11.154
live mouse astrocytes simulated with LP's,
which is a which is a molecule that can

00:16:11.154 --> 00:16:15.319
stimulate,
you know inflammatory responses.

00:16:15.320 --> 00:16:21.098
So here is like showing a bright field
images of the cells in device and

00:16:21.098 --> 00:16:26.560
corresponding final intensity increase
map at end of the experiment.

00:16:26.560 --> 00:16:31.019
So we first identify the location of the
cells and track cell position by

00:16:31.019 --> 00:16:35.600
recording and processing intensity
changes within that specific cell reach.

00:16:36.160 --> 00:16:42.273
So also like we show the intensity
increase over time and in this graph,

00:16:42.273 --> 00:16:48.973
so the the the ticket line is the median
values of the whole cells of the whole

00:16:48.973 --> 00:16:49.560
region.

00:16:50.000 --> 00:16:54.538
So we see us gathering the response that
we believe it is a, you know,

00:16:54.538 --> 00:16:56.840
biological cell to cell variability.

00:16:57.400 --> 00:17:02.097
So also we validated this platform
against a Lysa by normalizing the

00:17:02.097 --> 00:17:04.480
responses with the number of cells.

00:17:05.040 --> 00:17:08.800
So the device and a Lysa response is over
late on the graph.

00:17:08.800 --> 00:17:11.920
So they track each other over 24 hours.

00:17:13.160 --> 00:17:16.480
So the slope is like they agree to.

00:17:16.800 --> 00:17:21.832
So we want to show their lifestyle,
which is a gold standard method and our

00:17:21.832 --> 00:17:22.760
method agrees.

00:17:23.960 --> 00:17:24.680
Yeah, next one.

00:17:24.680 --> 00:17:29.452
Yeah,
this slide basically brings the the full

00:17:29.452 --> 00:17:33.920
platform together on the microfluidic
side.

00:17:33.920 --> 00:17:40.146
So the microfluidic device handles the
cells and reagent purging and drug and

00:17:40.146 --> 00:17:46.451
ligand delivery and also the the area of
tissue cultures for like parallel and

00:17:46.451 --> 00:17:51.720
high throughput cell culturing and
acquisition, data acquisition.

00:17:52.320 --> 00:17:58.079
So the the robotic pipette brings the
tissues and organised directly on top of

00:17:58.079 --> 00:18:03.109
the on top of the chambers and the entire
state sits on a, you know,

00:18:03.109 --> 00:18:05.880
microscope in a controlled atmosphere.

00:18:06.480 --> 00:18:12.752
So the the other optical side,
we have this dual measurement system

00:18:12.752 --> 00:18:15.520
within the same field of view.

00:18:15.920 --> 00:18:21.040
We have two outputs from spectrometer and
also the camera.

00:18:22.160 --> 00:18:28.223
So we can get sensor data and also at the
same time we can have the morphological

00:18:28.223 --> 00:18:33.400
track the location of the cells and
obtain the morphological changes.

00:18:33.960 --> 00:18:37.440
So actually this is a unique combination
of everything.

00:18:38.640 --> 00:18:45.672
That combination is exactly what LED us
to measure all like tissue responses to

00:18:45.672 --> 00:18:52.880
dynamic and combined like stimuli at high
throughput, which is our original goal.

00:18:56.240 --> 00:19:00.293
Yeah,
this is a very much like a team effort

00:19:00.293 --> 00:19:07.320
from Biohop Chicago and Biohop San
Francisco and our group from Northwestern.

00:19:09.120 --> 00:19:15.868
Thank you everyone that's shown here for
experimental and engineering work and for

00:19:15.868 --> 00:19:19.040
Chan Zuckerberg Biohub for the funding.

00:19:22.440 --> 00:19:26.050
Thank you,
Doctor Sun and the Doctor Sarikaya for

00:19:26.050 --> 00:19:28.000
the excellent presentation.

00:19:29.080 --> 00:19:34.584
I especially appreciate the integration
of delivery technologies with real time

00:19:34.584 --> 00:19:35.960
cellular monitoring.

00:19:36.720 --> 00:19:41.720
This type of platform could be very
powerful for understanding complex

00:19:41.720 --> 00:19:43.200
biological responses.

00:19:44.120 --> 00:19:47.610
And again,
I invite the audience to continue

00:19:47.610 --> 00:19:50.480
submitting questions to the chat box.

00:19:52.840 --> 00:19:55.280
We will move to the next speaker.

00:19:55.680 --> 00:20:00.000
Next speaker will be Professor Michael
Rasponi.

00:20:01.440 --> 00:20:08.691
Professor Rasponi is a full professor of
bioengineer at Political Milano,

00:20:08.691 --> 00:20:16.138
where he has Mimi clap within the
Department of Electronics Information and

00:20:16.138 --> 00:20:18.000
the bioengineering.

00:20:18.440 --> 00:20:25.651
His research focus on organ on cheap
platforms that integrate microfluids,

00:20:25.651 --> 00:20:33.151
bio mechanics and electronic stimulation
and the human cell biology to modern

00:20:33.151 --> 00:20:39.402
cardiac, musculoskeletal,
gastrointestinal and pulmonary tissues

00:20:39.402 --> 00:20:46.902
with a strong translational orientation
towards drug discovery and the safety

00:20:46.902 --> 00:20:47.960
assessment.

00:20:48.560 --> 00:20:55.481
He is Co founder of Biomix Xer
Polytechnical Denominus spin off

00:20:55.481 --> 00:21:01.430
translation organic chip technology into
pharma R&amp;

00:21:01.430 --> 00:21:09.974
D workflows and the currently serve as
the chair of the European Organ on Chip

00:21:09.974 --> 00:21:10.839
Society.

00:21:11.560 --> 00:21:15.160
So we're delighted to have you with us.

00:21:15.520 --> 00:21:18.600
Please go ahead Doctor Michael Rasponi.

00:21:21.680 --> 00:21:23.640
OK, let me share the screen.

00:21:27.400 --> 00:21:27.880
Can you see it?

00:21:29.000 --> 00:21:32.160
No, not yet.

00:21:33.080 --> 00:21:34.680
OK, now I think so.

00:21:36.560 --> 00:21:38.320
Yeah, please.

00:21:38.320 --> 00:21:38.600
OK.

00:21:39.240 --> 00:21:40.000
Yeah, thank you.

00:21:40.920 --> 00:21:45.920
Thank you for the introduction and thank
you everybody for attending this webinar.

00:21:47.320 --> 00:21:55.537
So in the next two slides, on 2 slides,
I will try to guide you to research that

00:21:55.537 --> 00:22:01.320
we published on APL by Engineering 2018,
so 8 years ago.

00:22:02.240 --> 00:22:08.840
And the rationale behind this publication
was a question, a biological question.

00:22:08.840 --> 00:22:16.039
So how to improve the operation and the
functionality of a mutilised cardiac

00:22:16.039 --> 00:22:16.600
model.

00:22:17.360 --> 00:22:21.880
And at that point that year,
actually two years before we had a

00:22:21.880 --> 00:22:24.000
publication already submitted.

00:22:24.040 --> 00:22:31.140
I will try to share that with the video
in which we developed a platform made of

00:22:31.140 --> 00:22:32.280
PDMS able to.

00:22:32.480 --> 00:22:40.546
Here you see 3 chambers all actuated with
the same line and each of them was filled

00:22:40.546 --> 00:22:47.077
with a gel containing cells,
cardiac cells in a 3D environment in a

00:22:47.077 --> 00:22:54.760
farming job and separated by two side
channels here in blue serving as vessels.

00:22:56.120 --> 00:23:02.043
And once polymerized the actuation
chamber was actually used to provide the

00:23:02.043 --> 00:23:08.433
mechanical cyclic loading which actually
turned into uniaxial strain to cells and

00:23:08.433 --> 00:23:12.720
that turns like training mechanical
training to cells.

00:23:12.800 --> 00:23:18.737
The sensors at that time was not a red
caldiomyosides in a ratio of 70 to 30%

00:23:18.737 --> 00:23:23.000
caldiomyosides and and stromer cells
mostly fibroblast.

00:23:23.720 --> 00:23:27.634
So the idea,
with that idea we went on adding,

00:23:27.634 --> 00:23:34.465
we kept all the essential elements which
proved to be useful and we added another

00:23:34.465 --> 00:23:38.297
element which were two electrical
electrodes,

00:23:38.297 --> 00:23:44.127
stainless electrodes which were fitting
inside the flanking channels,

00:23:44.127 --> 00:23:46.960
so surrounding the gel with cells.

00:23:47.760 --> 00:23:52.422
And the first step and the aim was to
deliver not only a mechanical stimulation

00:23:52.422 --> 00:23:56.327
to cells, but also a bio,
an electrical stimulation and possibly a

00:23:56.327 --> 00:23:58.600
combined electromechanical stimulation.

00:23:59.800 --> 00:24:03.880
The first question was about the electric
field that was needed.

00:24:03.880 --> 00:24:08.703
So we did finite element simulation,
we are model and then we use two

00:24:08.703 --> 00:24:14.284
different types of simulation 111 base
basically exploring what was the state of

00:24:14.284 --> 00:24:15.800
the other at the time.

00:24:15.800 --> 00:24:22.264
So one the traditional one was to provide
a 5 Volt per centimeter electric field

00:24:22.264 --> 00:24:28.329
and the other one was to control the the
current providing a higher current

00:24:28.329 --> 00:24:32.239
density which was 74,000,
000 square centimetre.

00:24:33.840 --> 00:24:38.480
So the results,
the primary results you can see them here

00:24:38.480 --> 00:24:39.520
on the right.

00:24:39.520 --> 00:24:45.369
So the control providing a calcium dye
demonstrated that after five days of

00:24:45.369 --> 00:24:48.987
culture,
so no mechanical need your electrical

00:24:48.987 --> 00:24:52.989
simulation,
the cells were kind of sporadic beating

00:24:52.989 --> 00:24:59.147
while with pure electric field there was
a synchronization of the cells and the

00:24:59.147 --> 00:25:04.920
best result was achieved with five watts
per centimeter of electric field.

00:25:05.120 --> 00:25:10.400
So a mild field which was following a
pacing of one else.

00:25:10.840 --> 00:25:18.320
So with that we went on in our study and
we tried to see whether the electrical

00:25:18.320 --> 00:25:24.772
simulation was better or not of the
control of course the mechanical

00:25:24.772 --> 00:25:31.505
stimulation or if coupling them was
actually beneficial for the cardiac

00:25:31.505 --> 00:25:32.160
tissue.

00:25:32.760 --> 00:25:37.441
So what we got was an increase in all the
stimulations, so mechanical,

00:25:37.441 --> 00:25:41.133
mechanical or coupled in terms of
excitation threshold,

00:25:41.133 --> 00:25:46.672
so the the voltage that you need to apply
to for your cardiac tissue to follow your

00:25:46.672 --> 00:25:47.200
patient.

00:25:47.760 --> 00:25:52.105
And also we had an increase,
slight increase of the maximum capture

00:25:52.105 --> 00:25:54.725
rate,
so the maximum frequency that your

00:25:54.725 --> 00:25:58.880
cardiac tissue will follow your
simulation external stimulation.

00:26:00.160 --> 00:26:02.520
Also the protein gene, protein level.

00:26:03.440 --> 00:26:09.200
We had actually some not univocal results.

00:26:09.240 --> 00:26:14.859
I have to admit that the statistics at
that time was not that great,

00:26:14.859 --> 00:26:21.212
but we could actually see and add a
confirmation on what we saw functional in

00:26:21.212 --> 00:26:22.760
the functional way.

00:26:22.760 --> 00:26:27.925
So we had the increase of top point T and
connection .

00:26:27.925 --> 00:26:34.405
3 which is is a sign of a better
electrical connection cells in both

00:26:34.405 --> 00:26:37.880
electrical and mechanical simulation.

00:26:38.840 --> 00:26:48.190
And we had an increase of the maturation
of in terms of ratio of cardiac amazing 7

00:26:48.190 --> 00:26:49.880
over amazing 6.

00:26:52.160 --> 00:26:57.920
So that was basically our an inch point
for our research.

00:26:58.360 --> 00:27:01.585
And I,
I'd like to show you the road map of our

00:27:01.585 --> 00:27:05.617
research in the field,
which as I said in the beginning was

00:27:05.617 --> 00:27:06.760
starting in 2016.

00:27:06.840 --> 00:27:10.926
Then we had this paper published adding
electrical, electrical,

00:27:10.926 --> 00:27:13.800
mechanical situation on our cardiac
tissues.

00:27:14.240 --> 00:27:21.569
And then later on we moved from a red
cardiomycite source to a human IPS

00:27:21.569 --> 00:27:24.280
derived cardiomycite model.

00:27:24.600 --> 00:27:32.256
And that actually was way better in terms
of motivation and and functionality,

00:27:32.256 --> 00:27:39.913
even because the the gene levels were
much more clear on humans as as compared

00:27:39.913 --> 00:27:42.240
to to our rodent models.

00:27:43.040 --> 00:27:50.474
And after that we went on using and
exploiting the model to test drugs and

00:27:50.474 --> 00:27:54.440
molecules in cardiac safety environment.

00:27:55.920 --> 00:28:02.050
That was also a topic of the skin office
was introduced against the of for the

00:28:02.050 --> 00:28:03.680
technical by anemics.

00:28:04.000 --> 00:28:08.560
And recently our current research is on
on two sides.

00:28:08.560 --> 00:28:15.815
One is to use the model to explore the
model to for react safety purposes from

00:28:15.815 --> 00:28:20.040
from QT prolongation to arithmetic
detection.

00:28:20.680 --> 00:28:25.407
And the other one is to complexify a bit
the model from the biological point of

00:28:25.407 --> 00:28:28.067
view,
as we are at the end of the year cells

00:28:28.067 --> 00:28:29.839
which are actually announcing.

00:28:29.840 --> 00:28:33.803
Furthermore,
the motivation and the synchronization

00:28:33.803 --> 00:28:39.671
cells and the macrophages as well,
which are as well contributed in vivo and

00:28:39.671 --> 00:28:45.768
we are also that in view as well in each
as well on the stabilization of the in

00:28:45.768 --> 00:28:48.360
the long term of the CADIAC model.

00:28:50.240 --> 00:28:50.440
Yeah.

00:28:50.440 --> 00:28:54.070
With that,
I'm down with the presentation and I of

00:28:54.070 --> 00:28:58.840
course invite you to ask questions either
on this on other topics.

00:29:06.280 --> 00:29:06.600
Thank you.

00:29:06.600 --> 00:29:08.960
Marco Yi, I think you are on mute.

00:29:10.600 --> 00:29:10.880
Sorry.

00:29:11.280 --> 00:29:15.120
Thank you Raspanis for the very exciting
talk.

00:29:16.240 --> 00:29:20.328
Yeah,
so really very fascinating from the hot

00:29:20.328 --> 00:29:26.817
on cheap tour to real practical pre
communicate track screening and very

00:29:26.817 --> 00:29:27.440
useful.

00:29:27.640 --> 00:29:34.802
And I think our audience will put their
questions on the chat and we will read

00:29:34.802 --> 00:29:37.160
the their questions later.

00:29:37.600 --> 00:29:39.080
So we will move to the next.

00:29:40.760 --> 00:29:49.125
Next speaker will be Professor Ash Agaro,
a professor of biomedical engineering and

00:29:49.125 --> 00:29:56.595
the director of engineering and applied
physics for the Desai Seti Urology

00:29:56.595 --> 00:30:00.280
Institute at the University of Miami.

00:30:00.600 --> 00:30:08.185
He Co directs Engineering Career Cures,
A collaborative initiative of the

00:30:08.185 --> 00:30:15.360
Sylvester Comprehensive Cancer Center and
the College of Engineering.

00:30:15.920 --> 00:30:20.997
His undergrad degree from Indian
Institute of Technology and his PhD from

00:30:20.997 --> 00:30:26.280
the University of Florida are both in
material science and then engineering.

00:30:26.480 --> 00:30:32.336
He then gathered postal research
experience in biomedical engineering at

00:30:32.336 --> 00:30:38.112
Columbia University and at the with
Institute for Biologically Inspired

00:30:38.112 --> 00:30:40.840
Engineering at Harvard University.

00:30:41.360 --> 00:30:47.788
His expertise lies in the engineering of
physiologically relevant fluidic

00:30:47.788 --> 00:30:52.480
platforms that serve organ on chip,
organize on chip.

00:30:52.840 --> 00:31:00.104
They've organ slice and the recently
organ profusion preservation and

00:31:00.104 --> 00:31:03.840
transportation for whole human eyes.

00:31:07.920 --> 00:31:13.520
So please join me to welcome Professor
Agawa.

00:31:15.360 --> 00:31:16.920
Please begin your presentation.

00:31:17.360 --> 00:31:18.520
OK, thank you, Yi.

00:31:18.760 --> 00:31:20.160
Thanks for the invitation AIP.

00:31:20.160 --> 00:31:24.459
And it's really an honor to present and
also be in the same room with, you know,

00:31:24.459 --> 00:31:28.440
the stewards of science like Professor
White and Professor Yu who've been.

00:31:29.360 --> 00:31:33.729
And it's really nice when journals are
led by career scientists and because they

00:31:33.729 --> 00:31:37.560
understand how science is done and can
manage the reviews much better.

00:31:37.560 --> 00:31:42.000
So I really appreciate journals which are
headed by, you know, active researchers.

00:31:42.800 --> 00:31:45.200
And I've had an awesome experience.

00:31:45.200 --> 00:31:47.360
I guess I've served as a reviewer for
both of them.

00:31:47.440 --> 00:31:51.360
And then also Marco or Doctor Rasponi set
up the field really well.

00:31:51.360 --> 00:31:55.310
I don't have any data slides because this
was supposed to be just a favor of what

00:31:55.310 --> 00:31:55.600
we do.

00:31:56.080 --> 00:31:58.400
So I have a very high level overview of
what we do.

00:31:58.480 --> 00:32:02.600
The field used to be called tissue chips
and then organs and chips.

00:32:02.600 --> 00:32:05.124
And now it's clubbed into what,
in the US at least,

00:32:05.124 --> 00:32:06.920
it's called new approach methodology.

00:32:07.320 --> 00:32:10.993
And I'll just give you an overview,
assuming that you have enough of a

00:32:10.993 --> 00:32:15.184
background on what organs and chips are,
on what my lab does and how we think it

00:32:15.184 --> 00:32:17.720
distinguishes itself from the rest of the
field.

00:32:18.280 --> 00:32:21.520
So we have specifically focused on very
large volume microfluidics.

00:32:21.520 --> 00:32:23.600
In fact,
you can't even call them microfluidics.

00:32:24.040 --> 00:32:31.368
These are plastic based non PDMS pieces
that are not bonded together the way PDMS

00:32:31.368 --> 00:32:35.480
is permanently bonded to glass or other
PDMS.

00:32:35.880 --> 00:32:41.738
And these plastic pieces have formed the
bottom of a chip and the top of the chip

00:32:41.738 --> 00:32:46.953
and then fit into each other like
interlocking pieces of metal when they

00:32:46.953 --> 00:32:50.240
are clamped together using mechanical
forces.

00:32:50.240 --> 00:32:51.600
I'm not showing the clamp here.

00:32:52.040 --> 00:32:54.748
They are also,
they also sandwich between them these

00:32:54.748 --> 00:32:58.580
compressible rubber gaskets shown in
green that snake around each of those

00:32:58.580 --> 00:32:59.040
channels.

00:32:59.560 --> 00:33:03.837
And those compressible gaskets under
mechanical compression would create the

00:33:03.837 --> 00:33:04.560
fluidic seal.

00:33:04.800 --> 00:33:08.713
And now you have independent channels in
which you can manually place the

00:33:08.713 --> 00:33:12.892
biologies in these belts that we micro
machine into plastic and then a fluidic

00:33:12.892 --> 00:33:14.320
inlet and a fluidic outlet.

00:33:15.120 --> 00:33:19.500
The inlet and the outlet ports connect to
the cassette in a way that the clamping

00:33:19.500 --> 00:33:23.612
pressure of the cassette brings into
contact the inlet and the outlet of the

00:33:23.612 --> 00:33:23.880
chip.

00:33:23.880 --> 00:33:29.280
So you saw in this design multiple
problems that PDMS suffers from.

00:33:29.280 --> 00:33:33.324
But the most basic 1 is PDMS does not
allow for you to create very large

00:33:33.324 --> 00:33:36.040
clearance devices and still ensure
laminar flow.

00:33:36.600 --> 00:33:41.247
So what the the only secret sauce behind
these chips is that despite having

00:33:41.247 --> 00:33:45.771
clearances that in by, you know,
with Reynolds numbers calculations would

00:33:45.771 --> 00:33:49.685
not ensure laminar flow,
We still sort of ensure A laminar like

00:33:49.685 --> 00:33:54.577
flow using geometric features that we
machine into the device so that the fluid

00:33:54.577 --> 00:33:55.800
path remains linear.

00:33:56.400 --> 00:34:02.146
And that allows for you to place up to
2000 microns or 2mm big organoids in

00:34:02.146 --> 00:34:02.600
there.

00:34:02.600 --> 00:34:07.456
But what we want to solve for is the
perfusion and the imaging problem of

00:34:07.456 --> 00:34:10.803
organoids,
which usually are done in static system

00:34:10.803 --> 00:34:13.560
or worse if they're embedded in hydrogels.

00:34:13.560 --> 00:34:17.315
Like like you know,
if they're embedded in hydrogels,

00:34:17.315 --> 00:34:22.530
then they even need more perfusion and
transport so these organized can be

00:34:22.530 --> 00:34:24.200
manually placed in them.

00:34:24.200 --> 00:34:28.619
And we've over the last 10 years at the
University of Miami done a lot of work in

00:34:28.619 --> 00:34:32.877
mostly islet immune interactions for type
1 diabetes where we place pancreatic

00:34:32.877 --> 00:34:35.625
islets and we can flow in immune cells
into these,

00:34:35.625 --> 00:34:39.560
into these channels and watch an islet
immune attack occur in real time.

00:34:40.080 --> 00:34:41.560
Again, this is all PDMS 3.

00:34:41.560 --> 00:34:45.402
So it solves for, you know,
drug absorption problems that PDMS is

00:34:45.402 --> 00:34:50.060
notorious for and me and obviously many
other labs have have develop now a full

00:34:50.060 --> 00:34:54.601
many of different organ chips and the
hope and the dream is to do multi organ

00:34:54.601 --> 00:34:57.280
connection and get a systemic level
response.

00:34:58.440 --> 00:35:01.760
We just today got a paper accepted in
advanced science.

00:35:02.120 --> 00:35:05.240
If you've created an immunized organ
chips.

00:35:05.240 --> 00:35:08.880
So immune competent organs and chips is
also where the field is heading towards.

00:35:09.360 --> 00:35:11.603
So over the last 10-15 years,
since you know,

00:35:11.603 --> 00:35:15.553
the work really got attention by having a
kickstart through major funding at MIT

00:35:15.553 --> 00:35:19.552
and Harvard and I was lucky enough to be
at Harvard at that point working on hard

00:35:19.552 --> 00:35:20.040
on a chip.

00:35:20.760 --> 00:35:25.016
We have now progressed towards creating
more and more complex chips to doing the

00:35:25.016 --> 00:35:27.960
hard part of how do we translate this
into real impact.

00:35:28.520 --> 00:35:34.706
And the way that's happening is,
excuse me, let me move to the next slide,

00:35:34.706 --> 00:35:41.305
is really a lot of external factors that
are driving the excitement around this

00:35:41.305 --> 00:35:41.800
field.

00:35:41.800 --> 00:35:45.040
And the external factors have to do with
regulatory law.

00:35:45.440 --> 00:35:50.320
So in the US anyway and Europe is ahead
of US in that respect.

00:35:50.720 --> 00:35:57.071
The FDA modernization 2 point O that was
passed a couple of years ago now does not

00:35:57.071 --> 00:36:03.346
require for sponsors who want a clinical
trial approval to submit any animal data

00:36:03.346 --> 00:36:08.319
in lieu of getting approval for human
clinical phase on testing.

00:36:09.000 --> 00:36:11.130
So, you know,
a lot of excitement happened around,

00:36:11.130 --> 00:36:13.051
you know,
you can read this as you don't need

00:36:13.051 --> 00:36:13.720
animals anymore.

00:36:13.720 --> 00:36:18.289
But the hard part is you still have to
prove that the assay that you want to

00:36:18.289 --> 00:36:23.214
submit the data from in lieu of an animal
has to stand up to the validation of the

00:36:23.214 --> 00:36:28.080
same context of use in which you've used,
in which you would have used an animal.

00:36:28.520 --> 00:36:31.364
If you would have used,
let's say 100 rats,

00:36:31.364 --> 00:36:36.405
100 mice for proving that your drug is
not liver toxic for that very specific

00:36:36.405 --> 00:36:40.284
liver toxicity assay,
your liver chip needs to stand up to,

00:36:40.284 --> 00:36:43.128
needs to be qualified for the for the
same,

00:36:43.128 --> 00:36:45.520
same readout and in the same context.

00:36:45.600 --> 00:36:48.282
And so even though there's a lot of
excitement,

00:36:48.282 --> 00:36:52.754
we wrote this very sober piece in Nature
Communications couple of years ago now

00:36:52.754 --> 00:36:55.548
where we said,
let's not have organs and chips go

00:36:55.548 --> 00:36:59.740
through the same typical hype cycle where
whenever a new technology comes,

00:36:59.740 --> 00:37:02.200
there's a big hike,
there's really adopted.

00:37:02.720 --> 00:37:06.120
But then this happened with microfluidics
in early 90s.

00:37:06.120 --> 00:37:09.203
There is a Truss of dissolution where you
know,

00:37:09.203 --> 00:37:14.600
you you realize that this is not going to
solve every problem and it's only through

00:37:14.600 --> 00:37:18.520
very slow and sustained efforts that you
find a new plateau.

00:37:19.520 --> 00:37:22.445
This business,
this pipe cycle for new technologies is

00:37:22.445 --> 00:37:24.200
talk to Business School students.

00:37:24.200 --> 00:37:28.512
And so we took the same approach and
applied it to its organ organ chips and

00:37:28.512 --> 00:37:32.320
really laid down the pathway to avoid
that truffle disillusionment.

00:37:32.720 --> 00:37:36.263
And that pathway has to do with a lot of
interactions,

00:37:36.263 --> 00:37:39.806
such as like in this webinar where you
have, you know,

00:37:39.806 --> 00:37:43.800
audiences from many different specialties
talk to each other.

00:37:44.120 --> 00:37:47.909
So an engineer will keep designing more
and more complex systems,

00:37:47.909 --> 00:37:52.560
but that system has to be usable by a
biologist who often don't like complexity.

00:37:52.960 --> 00:37:56.570
And then more importantly,
it has to be in communication with

00:37:56.570 --> 00:38:01.228
industry as well as regulatory bodies on
what it would take to replace the drug

00:38:01.228 --> 00:38:05.769
testing paradigm as industry users,
all the assets that the regulatory bodies

00:38:05.769 --> 00:38:07.400
such as EFT accept the data.

00:38:08.200 --> 00:38:10.396
So with that,
I'll invite you to look at the papers

00:38:10.396 --> 00:38:12.466
we've published,
but I'll stop here as sort of a

00:38:12.466 --> 00:38:13.480
background on the field.

00:38:13.760 --> 00:38:14.600
Thank you very much.

00:38:22.920 --> 00:38:23.760
Yeah, thank you, Ashu.

00:38:24.520 --> 00:38:24.880
Thank you.

00:38:24.880 --> 00:38:28.880
All speakers, outstanding presentations.

00:38:29.360 --> 00:38:31.720
Ashley, it's such a question.

00:38:32.040 --> 00:38:37.520
Our presentations are focused on OK,
on the chip or tissue on the chip.

00:38:37.520 --> 00:38:43.791
So basically that means this technology
is really very important for drug

00:38:43.791 --> 00:38:46.080
delivery of drug screening.

00:38:46.400 --> 00:38:53.936
So I think for the discussion part,
I will ask all of you,

00:38:53.936 --> 00:39:04.282
So what will be the most challenging part
for this technology go from individual

00:39:04.282 --> 00:39:09.520
laboratory to clinical use in the future?

00:39:09.800 --> 00:39:18.903
And how far can we see the real
applications of this technology in drug

00:39:18.903 --> 00:39:20.800
delivery field?

00:39:22.560 --> 00:39:31.480
And I'd like to ask Doctor Song to Give
your opinion first.

00:39:35.600 --> 00:39:38.560
Yeah, yeah.

00:39:38.560 --> 00:39:43.171
So for the yes,
since I'm working with a high throughput

00:39:43.171 --> 00:39:49.723
chips which has a lot of chambers and
then simultaneously monitor many response,

00:39:49.723 --> 00:39:53.930
I think yeah,
this technology can be used to answer

00:39:53.930 --> 00:39:56.600
many like a biological questions.

00:39:57.120 --> 00:39:58.320
Like I mean, especially a biology.

00:39:58.320 --> 00:40:04.750
Even though let's say you have a skin
tissue disease like psoriasis or Melanoma,

00:40:04.750 --> 00:40:11.180
each patient causes a different cure is a
different even though you use the same

00:40:11.180 --> 00:40:13.799
like a drugs to like a cure them.

00:40:13.800 --> 00:40:15.960
You know, sometimes it works,
sometimes it does not work.

00:40:16.080 --> 00:40:20.160
And then so the high throughput or micro
fluidic device that.

00:40:21.480 --> 00:40:26.100
We are all developing with this platform
we are developing is going to be

00:40:26.100 --> 00:40:28.972
important in answering how the
stochasticity,

00:40:28.972 --> 00:40:33.530
how the like a different biology,
you know different biological contexts

00:40:33.530 --> 00:40:37.963
that can be tested and they can be
measured and then find out the core

00:40:37.963 --> 00:40:43.145
mechanism and all these data can be used
to find like a better like a therapeutics

00:40:43.145 --> 00:40:46.080
at the pedaler that the personal like a
lever.

00:40:46.080 --> 00:40:49.200
OK, thank you.

00:40:49.200 --> 00:40:57.880
So then Doctor Sarikaya, Yeah.

00:40:58.720 --> 00:41:04.137
So I think biggest challenge from lab to
like clinical transition is that simply

00:41:04.137 --> 00:41:07.682
making the device like sensitive or more
innovative,

00:41:07.682 --> 00:41:11.361
it's like just showing that it's robust,
reproducible,

00:41:11.361 --> 00:41:14.840
clinically useful in real patients,
but in the lab.

00:41:14.880 --> 00:41:20.458
So conditions are usually extremely
controlled and like clean buffers,

00:41:20.458 --> 00:41:23.680
snow concentrations, optimized protocols.

00:41:25.120 --> 00:41:30.080
But like in the real world environment,
that's not the case.

00:41:30.720 --> 00:41:33.867
So,
so to the device like maybe here like

00:41:33.867 --> 00:41:37.240
slightly different from like batch to
batch.

00:41:37.480 --> 00:41:43.920
So also like different users like may
handle like the essays like differently.

00:41:44.520 --> 00:41:48.093
So I think yeah,
that's the one of the biggest like core

00:41:48.093 --> 00:41:48.720
challenge.

00:41:49.400 --> 00:41:54.464
Can the technology, you know,
give accurate and consistent results

00:41:54.464 --> 00:41:59.000
across many patients,
many devices for a for a longer days?

00:42:00.520 --> 00:42:04.718
Yeah,
I think the biggest challenge is like

00:42:04.718 --> 00:42:11.876
showing the technique is robust,
reproducible and useful and tried in many

00:42:11.876 --> 00:42:13.880
patients and samples.

00:42:16.200 --> 00:42:17.640
Yeah, thank you.

00:42:17.720 --> 00:42:23.160
So then we'll move to Professor Raspani.

00:42:25.200 --> 00:42:26.520
Yeah, thank you for the question.

00:42:26.520 --> 00:42:32.600
I think I agree with both my colleagues
in for different reasons.

00:42:32.600 --> 00:42:39.635
So the also that the adoption can be
divided in adoption for collaborators and

00:42:39.635 --> 00:42:44.000
partners, so out of the lab,
but just next door.

00:42:44.080 --> 00:42:50.600
So for example in hospitals or in other
uses where the clinical question is there.

00:42:51.000 --> 00:42:54.477
So in that case,
I think the easiness of use,

00:42:54.477 --> 00:43:00.601
so the robustness of possibility of the
device is the key point because it's the

00:43:00.601 --> 00:43:06.120
first time the device goes in the hands
which are not May Engineer said.

00:43:06.480 --> 00:43:12.473
So our biologists need to use it as much
as possible in an easy way for the

00:43:12.473 --> 00:43:14.840
adoption in the larger extent.

00:43:14.840 --> 00:43:20.838
So the adoption of the modest,
the biological modest then that may occur

00:43:20.838 --> 00:43:25.440
only when there is a qualification of the
model itself.

00:43:26.080 --> 00:43:32.759
So that brings the topic of the context
of use which is very common in the M

00:43:32.759 --> 00:43:33.280
field.

00:43:33.280 --> 00:43:40.280
So every device can be qualified every
time for a specific context of use.

00:43:40.600 --> 00:43:48.294
So the for example for the heart despite
the the cardiac model is a cardiac model,

00:43:48.294 --> 00:43:53.579
it can do QT prolongation,
it can be it can do iythmiac,

00:43:53.579 --> 00:43:58.400
arrhythmic event fibrosis or whatever if
I qualify.

00:43:58.400 --> 00:44:03.898
So after validation which is scientific
but also qualification which is far

00:44:03.898 --> 00:44:06.720
mediated for a specific context of use.

00:44:06.720 --> 00:44:12.828
So the QT prorogation then that more than
would be only usable and used in depth

00:44:12.828 --> 00:44:13.960
context of use.

00:44:13.960 --> 00:44:18.195
If I want to change the context of use
then I have to go back to the basic

00:44:18.195 --> 00:44:21.640
ingredients of the biology and start over
the qualification.

00:44:21.800 --> 00:44:25.162
So I think there are different things to
be thought,

00:44:25.162 --> 00:44:29.920
and most of them need to be taught in the
beginning of the design process.

00:44:36.440 --> 00:44:39.320
We then moved to Professor Agua.

00:44:40.000 --> 00:44:42.995
Yeah,
I think everyone's saying the same things

00:44:42.995 --> 00:44:45.928
now,
so I'm happy to repeat it sort of more or

00:44:45.928 --> 00:44:46.240
less.

00:44:46.240 --> 00:44:49.567
Nice way of saying what Doctor Rasponi
was saying is the,

00:44:49.567 --> 00:44:54.328
the model we have in the lab is make the
chips simple enough that even a biologist

00:44:54.328 --> 00:44:54.959
can use it.

00:44:55.080 --> 00:44:59.744
It's not out of disrespect to biologists,
but essentially they're, you know,

00:44:59.744 --> 00:45:03.440
they're just not,
they're not used to having any complexity.

00:45:03.440 --> 00:45:05.160
You know, they want to follow protocol.

00:45:05.160 --> 00:45:07.540
And then it's often not the chip design
itself,

00:45:07.540 --> 00:45:10.120
it's the operation of the chip that's
more complex.

00:45:10.520 --> 00:45:15.165
So the chip can be simple enough,
but if you need a full suite of fluid

00:45:15.165 --> 00:45:19.359
handlers and valves and pumps and
manifolds to operate the chip,

00:45:19.359 --> 00:45:23.617
that is often underlooked and I would,
I would argue underfunded,

00:45:23.617 --> 00:45:25.360
at least in the US as well.

00:45:25.480 --> 00:45:28.880
Like developing a fluid architecture,
fluidic control architecture.

00:45:29.320 --> 00:45:32.694
If you write that into a brand,
there is no study section that will be

00:45:32.694 --> 00:45:35.451
interested in funding it because it's
just not, you know,

00:45:35.451 --> 00:45:37.400
cool enough because it's not new science.

00:45:37.400 --> 00:45:38.800
It's a, it's a tool development.

00:45:39.320 --> 00:45:43.440
So not enough attention on operating the
tool, operating the chip.

00:45:43.440 --> 00:45:46.520
It is either from funding or from
development.

00:45:47.480 --> 00:45:50.898
And to, you know,
the second point that also queuing off of

00:45:50.898 --> 00:45:53.975
what Marco was saying,
just the example of cardiotox,

00:45:53.975 --> 00:45:55.399
it's unbelievable, right?

00:45:55.400 --> 00:46:01.252
Like every drug shows cardiotoxicity and
the only assay is you know that you

00:46:01.252 --> 00:46:06.040
transfer that your cells with the ion
channel that has the QD.

00:46:06.280 --> 00:46:09.680
You know that that you can show the QD
prolongation on that's on a single ion

00:46:09.680 --> 00:46:10.640
channel level readout.

00:46:10.800 --> 00:46:14.828
And the next readout,
at least in the FDA regulatory law is is

00:46:14.828 --> 00:46:19.176
dog you go right from a single ion
channel to a complete, you know,

00:46:19.176 --> 00:46:24.100
large animal and there isn't any tissue
level readout that's fully validated

00:46:24.100 --> 00:46:28.960
today by the FDA when arrhythmia is an
emergent property of multiple cells.

00:46:29.520 --> 00:46:34.411
So if the if the risk, you know, is,
is if the point is to show a pro

00:46:34.411 --> 00:46:39.792
arrhythmogenic propensity of a drug,
I would argue there is a huge gap in in

00:46:39.792 --> 00:46:45.383
the dimensions of like of where you can
go from a single iron channel to a full

00:46:45.383 --> 00:46:47.200
full organ, a full animal.

00:46:47.800 --> 00:46:51.415
And that gap is being filled through
efforts by Doctor Rasponi and others who

00:46:51.415 --> 00:46:52.760
are developing those systems.

00:46:52.760 --> 00:46:56.301
And that's such a neat,
clear context of use that these devices

00:46:56.301 --> 00:46:56.800
can fill.

00:46:57.920 --> 00:47:01.827
I'm very bullish around, you know,
especially heart on a chip and liver on a

00:47:01.827 --> 00:47:04.720
chip for showing toxicity,
for revealing human toxicity.

00:47:07.600 --> 00:47:09.200
Thank you, Ashley.

00:47:09.280 --> 00:47:12.440
So thank you all for the answers.

00:47:12.600 --> 00:47:17.120
So we have a question from the audience.

00:47:17.640 --> 00:47:18.600
I will read it.

00:47:18.600 --> 00:47:26.720
So I think it's a audience from Eric.

00:47:26.720 --> 00:47:31.126
So he he wrote in his field of
coordination chemistry,

00:47:31.126 --> 00:47:37.374
truck delivery system plays a crucial
role in advanced truck delivery systems

00:47:37.374 --> 00:47:42.902
through the synthesis of therapeutic
metal complex such as platinum,

00:47:42.902 --> 00:47:48.189
silver and the copper complex,
controlling the stability of metal

00:47:48.189 --> 00:47:52.515
complexes and regulating their drug
release behavior,

00:47:52.515 --> 00:47:55.799
thereby improving therapeutic efficiency.

00:47:56.520 --> 00:48:01.250
Conjugated meta complex with
nanoparticles or polymer carriers to

00:48:01.250 --> 00:48:04.547
enhance target drug delivery to cancer
cells,

00:48:04.547 --> 00:48:08.919
increase bio availability and then
minimize system toxicity.

00:48:09.160 --> 00:48:11.040
I think it's just a comment.

00:48:11.040 --> 00:48:17.835
So basically I think with the advanced
organ on the chip technology,

00:48:17.835 --> 00:48:25.320
those system can also be tested with
those organic chip platforms for sure.

00:48:25.800 --> 00:48:34.040
So I think look all your talk were
inspired the audience to use this.

00:48:35.880 --> 00:48:40.000
So I will move to another question I have.

00:48:40.000 --> 00:48:46.604
So basically now you see the artificial
intelligence and the machine learning

00:48:46.604 --> 00:48:50.160
have been widely using almost every field.

00:48:50.160 --> 00:48:55.520
So how do you see this technology can be
used in drug delivery?

00:48:56.040 --> 00:49:04.754
How where this technology maybe bring
something new or even revolutionize drug

00:49:04.754 --> 00:49:10.269
delivery,
especially we have very diverse samples

00:49:10.269 --> 00:49:15.123
or the results from different
technologies,

00:49:15.123 --> 00:49:23.506
whether they can be combined or can be
the data can be synthesized using AI

00:49:23.506 --> 00:49:24.720
technology.

00:49:27.040 --> 00:49:31.760
I will start with Professor Song, please.

00:49:32.280 --> 00:49:32.680
Yes.

00:49:33.800 --> 00:49:38.400
So I'm not really chemistry and trouble
delivery is a little bit out of my focus.

00:49:39.160 --> 00:49:45.486
But I do know that there are many micro
fluidic devices that's used for the for

00:49:45.486 --> 00:49:51.260
testing drug deliveries like droplet
generator for mixing many different

00:49:51.260 --> 00:49:57.824
components or like small matters and then
testing how how it goes inside a cell or

00:49:57.824 --> 00:49:59.960
I mean something like that.

00:49:59.960 --> 00:50:00.840
I mean at the end.

00:50:01.440 --> 00:50:05.296
So with micro fluidic device, I mean,
because it's a controlling very small

00:50:05.296 --> 00:50:08.900
fluid and they're very precisely,
I think it can be used to create all

00:50:08.900 --> 00:50:12.960
these kind of different combinations you
can think about and then monitor them.

00:50:13.440 --> 00:50:18.860
And to answer your questions on Doctor
Kao, the AI is, you know,

00:50:18.860 --> 00:50:25.615
is already like changing many things in
the fear that especially in the biology,

00:50:25.615 --> 00:50:31.786
I mean, especially in the bio hub,
I would say that one of the goal is to

00:50:31.786 --> 00:50:36.039
make a virtual like immune system or
virtual cell.

00:50:36.520 --> 00:50:39.664
So this, you know,
this is basically rather than solving,

00:50:39.664 --> 00:50:43.350
I mean, stabling the equations,
the differential equations and then

00:50:43.350 --> 00:50:47.307
establishing the signaling networks that
that's happening inside of say,

00:50:47.307 --> 00:50:48.880
watching regulatory networks.

00:50:49.480 --> 00:50:52.235
But now the approach seems like it has a
lot,

00:50:52.235 --> 00:50:57.027
we have a lot of data and the technology
has been developed so much that it can

00:50:57.027 --> 00:51:01.280
generate a lot of data or so
simultaneously in one where 2 like trials

00:51:01.280 --> 00:51:01.760
as well.

00:51:02.120 --> 00:51:05.704
So once we have these 10,
000 datas from these samples,

00:51:05.704 --> 00:51:10.568
then we have a multiple like inputs of
the high throughput devices that I'm

00:51:10.568 --> 00:51:15.816
making while other peoples are making and
we can use the AI motor to connect this

00:51:15.816 --> 00:51:16.840
input to output.

00:51:16.840 --> 00:51:21.957
It's kind of a black box right now,
but AI can kind of a link between these

00:51:21.957 --> 00:51:25.123
two,
especially the batteries are very complex

00:51:25.123 --> 00:51:27.480
and it's a very stochastic as well.

00:51:28.080 --> 00:51:33.107
And so it can be used to kind of a hair
to guess what's the like,

00:51:33.107 --> 00:51:39.429
what's wrong with these patients and then
what's what's the best like combinations

00:51:39.429 --> 00:51:44.000
of the drugs or the drug delivery systems
that can be used.

00:51:47.000 --> 00:51:47.520
Thank you.

00:51:52.200 --> 00:51:56.000
So now we move to Doctor Sarikaya.

00:51:57.040 --> 00:51:57.280
Yeah.

00:51:58.000 --> 00:51:58.200
Yeah.

00:51:58.240 --> 00:52:00.120
I agree with Doctor Sun.

00:52:00.120 --> 00:52:06.880
So AI like enables a lot of things that
we cannot even think of before.

00:52:06.880 --> 00:52:10.645
So,
but like AI or machine learning will not

00:52:10.645 --> 00:52:16.920
replace the real experimentation like
drug in terms of like drug delivery.

00:52:17.080 --> 00:52:19.280
Also the other type of research too.

00:52:19.880 --> 00:52:24.780
But it's the AI can make,
make them like much more efficient like

00:52:24.780 --> 00:52:30.052
by guiding the formulation design,
like doing the experimental design,

00:52:30.052 --> 00:52:33.320
even like predicting some of the
responses.

00:52:33.320 --> 00:52:37.600
We can like remove them from the
experimentation from the get go.

00:52:38.080 --> 00:52:43.852
So that enables like more like
personalized, like feedback control,

00:52:43.852 --> 00:52:45.720
like delivery systems.

00:52:46.560 --> 00:52:52.800
But the key challenge I believe is like
still like building like high quality

00:52:52.800 --> 00:52:58.960
experimental data set that that makes
those models like more trustworthy and

00:52:58.960 --> 00:53:00.400
clinically useful.

00:53:02.680 --> 00:53:03.200
Thank you.

00:53:03.480 --> 00:53:08.320
So I'd like to hear from Professor
Rasponi.

00:53:08.920 --> 00:53:09.240
Thank you.

00:53:10.480 --> 00:53:16.240
Yeah, of course,
I agree on on the use of the AI.

00:53:17.560 --> 00:53:23.717
But another another way it's impacting,
at least with me,

00:53:23.717 --> 00:53:31.999
is I'm more and more challenging my ideas,
designing experiments on readouts,

00:53:31.999 --> 00:53:37.520
which makes sense on literature which is
published.

00:53:37.520 --> 00:53:42.160
So it's like conversating with a very
smart collaborator,

00:53:42.160 --> 00:53:48.720
which has a lot of information from the
literature and as a first acting when you

00:53:48.720 --> 00:53:54.000
plan and you experience to target a
possible biological question,

00:53:54.000 --> 00:53:57.680
it's becoming very useful because it
doesn't,

00:53:57.680 --> 00:54:03.920
it's not the AI tools are not that wrong
anymore on AI, on literature search.

00:54:03.920 --> 00:54:10.830
So that is something that is actually
changing the way we as a group plan our

00:54:10.830 --> 00:54:12.160
our experience.

00:54:12.480 --> 00:54:16.920
And the second is again,
erect cardiac and become annoying.

00:54:16.960 --> 00:54:23.278
I know,
but there are there are tools which try

00:54:23.278 --> 00:54:24.200
to use.

00:54:33.290 --> 00:54:35.789
Sorry,
I believe we might have lost Marco's

00:54:35.789 --> 00:54:36.130
audio.

00:54:40.040 --> 00:54:46.871
This feedback loop is not easy because
the biological transfer function is

00:54:46.871 --> 00:54:47.600
complex.

00:54:47.600 --> 00:54:51.480
But with AI there are some ways to
simplify that.

00:54:51.760 --> 00:54:58.988
And so to get to what at the end,
a model which is always similar to the

00:54:58.988 --> 00:54:59.880
target 1.

00:54:59.920 --> 00:55:06.094
So having an endpoint,
which is a second point for Drug

00:55:06.094 --> 00:55:12.048
Administration,
which is always kind of standardised,

00:55:12.048 --> 00:55:12.600
yeah.

00:55:12.640 --> 00:55:15.600
Then so Professor Agua.

00:55:17.240 --> 00:55:17.520
Yeah.

00:55:18.240 --> 00:55:21.463
So I think everyone's saying the same
thing almost now,

00:55:21.463 --> 00:55:26.240
but the way I think about AI also is that
breaking barriers between finals, right?

00:55:26.240 --> 00:55:32.458
It's really like if the question that if
the harder answers are unlim,

00:55:32.458 --> 00:55:36.400
if finding hard answers is important,
right?

00:55:36.960 --> 00:55:41.586
The next blockbuster drug,
it probably won't come from one area of

00:55:41.586 --> 00:55:42.760
expertise, right?

00:55:42.760 --> 00:55:47.147
So because the body is so complex and you
know, the the complex diseases,

00:55:47.147 --> 00:55:51.773
the most devastating diseases are the
ones that affect multiple organ systems

00:55:51.773 --> 00:55:54.560
that interact with each other in
pathogenesis.

00:55:55.720 --> 00:56:00.026
That becomes really challenging to study
when the science, the way it is set up,

00:56:00.026 --> 00:56:02.950
at least in the US, you know,
you can think about NIH,

00:56:02.950 --> 00:56:07.203
it has 30 or 35 different institutes,
and you can pick your tissue of choice or

00:56:07.203 --> 00:56:08.160
disease of choice.

00:56:08.160 --> 00:56:09.440
And there's an institute for that.

00:56:09.800 --> 00:56:14.969
But there is not an institute that forces
people to not just look into, you know,

00:56:14.969 --> 00:56:18.499
what that field,
what that particular field looks into,

00:56:18.499 --> 00:56:23.480
but actually learn from information that
might be trapped in a different silo.

00:56:23.760 --> 00:56:25.800
And it could take decades to surface.

00:56:26.440 --> 00:56:31.378
And what AI now allows people to do is to
rapidly access the information that's

00:56:31.378 --> 00:56:34.280
buried in silos they would have never
visited.

00:56:34.880 --> 00:56:38.330
And that that connection,
that key scientific connection is,

00:56:38.330 --> 00:56:40.480
is left up to chance, you know, right.

00:56:40.480 --> 00:56:44.760
Like you meet at a in a happy hour,
you meet at a water cooler.

00:56:44.960 --> 00:56:46.760
And that's when those interactions happen.

00:56:46.760 --> 00:56:51.321
I just think those interactions are
enabled by in a way that I hadn't

00:56:51.321 --> 00:56:52.560
appreciated before.

00:56:53.160 --> 00:56:56.140
And then in the same timeline,
the organ ships are becoming more and

00:56:56.140 --> 00:56:59.640
more complex and you're adding more and
more organs that can talk to each other.

00:56:59.640 --> 00:57:04.303
And I just think it's the combination of
of both accessing information and silos

00:57:04.303 --> 00:57:09.198
very far away from your area of expertise,
but also the chips becoming more and more

00:57:09.198 --> 00:57:13.286
complex that you can now, you know,
use these very powerful systems to

00:57:13.286 --> 00:57:17.489
generate hypothesis that need information
from multiple silos and tools,

00:57:17.489 --> 00:57:21.520
which are also from multiple labs
together to answer those questions.

00:57:21.520 --> 00:57:22.720
And that would be very interesting.

00:57:24.400 --> 00:57:24.880
Thank you.

00:57:25.440 --> 00:57:29.000
So let's ask the last question.

00:57:29.000 --> 00:57:35.280
So do you have any comments for early
career researchers?

00:57:36.920 --> 00:57:38.520
I think anyone can answer it.

00:57:38.800 --> 00:57:41.800
I think just it's a very uncomfortable
space for a new research.

00:57:41.800 --> 00:57:44.160
It's both very exciting,
but very uncomfortable as well.

00:57:44.440 --> 00:57:48.698
Like already when we had to train people
in, especially in organs and chips,

00:57:48.698 --> 00:57:53.068
they used to, some of them would just be,
you know, like a deer in headlights,

00:57:53.068 --> 00:57:53.400
right?

00:57:53.400 --> 00:57:55.760
Like they just think, oh,
I have to learn biology.

00:57:55.760 --> 00:57:57.440
I have to learn the physics of
microfluidics.

00:57:57.440 --> 00:57:58.640
I have to learn fabrication.

00:57:58.920 --> 00:58:00.160
I have to learn CAD modeling.

00:58:00.160 --> 00:58:03.440
I have to learn, you know,
computational flow dynamics.

00:58:03.880 --> 00:58:07.783
And now you add on the AI and, you know,
there's just no excuse to be afraid of

00:58:07.783 --> 00:58:08.320
complexity.

00:58:08.320 --> 00:58:12.320
But I just think this is also a very rich
training environment for early careers.

00:58:12.320 --> 00:58:16.800
So the only advice is don't be afraid of
complexity and die down.

00:58:18.960 --> 00:58:22.755
Yeah,
maybe I can follow up on this because,

00:58:22.755 --> 00:58:27.562
yeah, I, I think,
I think one thing that if you, if you,

00:58:27.562 --> 00:58:32.960
if you're a young researcher wants to
really work in the field.

00:58:33.600 --> 00:58:37.520
I was just to become like bilingual in
engineering and biology.

00:58:38.120 --> 00:58:42.822
Because the this field,
at least the numb field is,

00:58:42.822 --> 00:58:44.360
is very exciting.

00:58:45.160 --> 00:58:50.054
And one of the reasons that makes the
field very exciting is that there is room

00:58:50.054 --> 00:58:54.336
on the table to speak at the same level
with the doctors, biologists,

00:58:54.336 --> 00:58:56.599
engineers and everybody in the field.

00:58:56.880 --> 00:59:00.840
So there are no structures at the moment.

00:59:00.840 --> 00:59:06.403
So it's important to understand exactly
what what are the issues and what are the

00:59:06.403 --> 00:59:11.967
possible solution And as a follow up on
the complexity and never get in love with

00:59:11.967 --> 00:59:13.800
the with the with the chip.

00:59:14.080 --> 00:59:16.760
The chip is just a mean to achieve a goal.

00:59:17.520 --> 00:59:21.000
It's not the final destination of the
research.

00:59:23.400 --> 00:59:24.920
Yeah, thank you.

00:59:24.960 --> 00:59:29.800
So we are approaching the end of the hour,
so we have to wrap up.

00:59:29.840 --> 00:59:35.920
So on behalf AIP Publishing and the
participating journals API,

00:59:35.920 --> 00:59:41.430
Bioengineering, Bio,
Microflix and the news also you have

00:59:41.430 --> 00:59:42.000
sorry.

00:59:42.000 --> 00:59:47.960
So we are unable to do more discussion.

00:59:47.960 --> 00:59:48.880
Sorry for that.

00:59:49.480 --> 00:59:54.718
So I would like to sincerely thank all
our speakers for sharing their exciting

00:59:54.718 --> 00:59:57.040
work and the software perspectives.

00:59:57.720 --> 01:00:03.000
I also thank our audience for joining us
for contributing excellent questions.

01:00:03.960 --> 01:00:09.316
Today's quick discussion has clearly
showing that drug delivery is no longer a

01:00:09.316 --> 01:00:11.080
single discipline problem.

01:00:11.480 --> 01:00:16.076
It requires the integration of
engineering, materials, biology,

01:00:16.076 --> 01:00:20.960
biophysics, microphilics, sensing,
and the translation of magazine.

01:00:21.840 --> 01:00:27.544
I hope this webinar has provide useful
insights into both the current state and

01:00:27.544 --> 01:00:30.040
the future direction of this field.

01:00:30.680 --> 01:00:37.680
Thank you again for attending the In Agra
Bioscience Research Spotlight webinar.

01:00:37.960 --> 01:00:41.480
We look forward to seeing you at future
sessions.

01:00:42.640 --> 01:00:46.243
And finally,
we'd like to thank Austin for the

01:00:46.243 --> 01:00:47.240
coordination.

01:00:47.560 --> 01:00:48.240
Thank you all.

01:00:48.360 --> 01:00:49.640
Have a wonderful day.

01:00:52.480 --> 01:00:53.240
Thank you, everyone.

01:00:53.280 --> 01:00:53.720
Thank you.

01:00:54.720 --> 01:00:55.120
Thank you.

01:00:55.680 --> 01:00:55.960
Bye bye.

01:00:55.960 --> 01:00:56.280
Thank you.

01:00:56.480 --> 01:00:59.240
Bye, Justin.